ABSTRACT

Can medical face masks be replaced by reusable community face masks with similar performance? The influence of the number of wash cycles, the wash temperature and the use of detergent was evaluated on the performance of one medical face masks (MFM) and ten community face masks (CFM). The performance of the new and washed masks was characterized from the bacterial filtration efficiency (BFE) and the differential pressure (DP). The tests on the new masks showed that the MFM had always better BFE than CFMs. Although two of the CFMs showed a BFE value exceeding 95%, only one can be classified as type I MFM based on both BFE and DP requirements. The influence of the washing parameters was investigated on the MFM and these two CMFs with excellent BFE properties. The parameters had no effect on the BFE of CFMs whilst the MFM exhibited a loss in efficiency when washed with detergent. The DP of masks were not impacted by the washing. The results clearly show that even though a compromise has to be made between the BFE and breathability, it seems possible to manufacture CFMs with performances similar to a type I MFM, without achieving type II requirements.


Subject(s)
COVID-19 , Masks , Detergents , Filtration , Humans
2.
Sci Rep ; 12(1): 1188, 2022 01 24.
Article in English | MEDLINE | ID: covidwho-1648659

ABSTRACT

As a result of the current COVID-19 pandemic, the use of facemasks has become commonplace. The performance of medical facemasks is assessed using Bacterial Filtration Efficiency (BFE) tests. However, as BFE tests, require specific expertise and equipment and are time-consuming, the performance of non-medical facemasks is assessed with non-biological Particle Filtration Efficiency (PFE) tests which are comparatively easier to implement. It is necessary to better understand the possible correlations between BFE and PFE to be able to compare the performances of the different types of masks (medical vs. non-medical). In this study BFE results obtained in accordance with the standard EN 14683 are compared to the results of PFE from a reference test protocol defined by AFNOR SPEC S76-001 with the aim to determine if BFE could be predicted from PFE. Our results showed a correlation between PFE and BFE. It was also observed that PFE values were higher than BFE and this was attributed to the difference in particle size distribution considered for efficiency calculation. In order to properly compare these test protocols for a better deduction, it would be interesting to compare the filtration efficiency for a similar granulometric range.


Subject(s)
COVID-19/prevention & control , Masks , Pandemics/prevention & control , SARS-CoV-2 , Filtration , Humans , Particle Size